Low-pressure kitchen faucet is need for Phigerat non-pressurized open vent boiler tank

This article briefly introduces the meaning of water pressure, to compare the working principles of a normal faucet and a low-pressure faucet.
Better understanding the non-pressurized system will help you make better choices on the under sink water system.
For the boiling water system, we usually say it non-pressure under sink water system. During our marketing service work, the most frequent reminder we share our customers is that: Phigreat’s boiling water system is the style of a non-pressure water system. The pressure vent is not on the boiler itself, but it is the outlet of the tap. So our boiler needs to be equipped with a special low-pressure water tap.

There were some customers did not get clearly the working principle of the whole system, they connect their normal kitchen faucet to the Phigreat’s water boilers. Which caused some damage and leakage of the water boilers.
Thus, there is a demand for our this article to give a detailed introduction on low-pressure tap and non-pressurized water heaters, we also call it water boilers.
Topic: Pressure of the Boiler
Firstly, we need to clarify “the pressure” refers to hereby?
This pressure does not refer to the water pressure from the house valve but refers to the pressure for the storage tank of the water boiler.
Two sources for the pressure of the hot water tank come from, one is the water pressure iteself, the other is the steam pressure during the water heating.
(1)、The water pressure from the water storage tank.
According to the pressure formula, F = PS = ρghS (ρ is the density of water, g is a constant 9.8N/kg counted as 10N/kg, h is the depth of the water, S is the bottom area of the water tank)
We can calculate the bottom pressure of the water tank of the 2.4L our water boiler as (height=20cm, diameter=12cm):
F=PS=ρghS=1.0×10³×10×0.2×3.14×(12/2/100) 2≈20N=2kgs
(2)、The water pressure of the municipal water supply.
Without calculating complexly for gravity-fed in a gravity-fed system, we can test it easily, we can connect a water pressure reading meter at the water supply end, we will be able to know the value of the water pressure, the normal water pressure is generally between 40 and 60PSI, most of the family will adjust at 50PSI, it is about 3.5kgs.
When water boiler is connected to a normal faucet supplies normal hot and cold water, then the water tank needs to be withstand by 2kgs + 3.5kgs = 5.5kgs of pressure without heating process, which is about 80PSI of pressure. So a normal cold water tank has 5.5kgs pressure during working.
When we calculate the pressure of steam, To image water is heated into 98 degrees, you will check out that there is a great risk of broken the water tank if there is no vent on the boiler.
The method of calculating steam pressure is complicated, so instead of explaining it by details here, the following calculation link is showed for refernce. https://www.quora.com/How-can-I-calculate-the-pressure-inside-a-sealed-tank-in-which-water-is-being-heated
The fifference between normal faucet and Non-pressurised water tap works


When a traditional kitchen faucet does not work, its spout in a completely closed position and without any overflow.
If you connect an ordinary faucet to a water boiler without a vent, the domestic water will go through a hose into the tank, then flows out from a hot water pipe.It means we are heating a sealed tank full of water, the water boiler bears not only the water pressure but also the steam pressure when water boiling, water trapped in the tank, simply due to the thermal expansion of the liquid, it will make the pipe or boiler break. It is easy to understand that the boiler is bearing very high pressure. We can call such systems as high-pressure water systems, there are some items like Quooker products in the market.